OUTDO HC12A-MF High Performance Factory Activated motorcycle battery, 12V 10Ah, maintenance-free

High Performance Factory Activated

Motorcycle Battery

Key Features of Our High Performance Factory Activated

  • When under -18℃ temperature environment, the battery keeps a high CCA value and has excellent low temperature performance of high current discharge, and it even remains the starting performance at 40°C low temperature.
  • Complete new structural design, and minimum the internal resistance and maximized the plate electrochemical reaction area.
  • The battery active substance adopted special organic additives which slower down the passivation of the negative plate and improve the effective specific surface area of the active material.
  • The grids are made of multiple lead alloy, which enhances the corrosion resistance and prolongs the battery life.
  • Higher output capacity, charging capacity and charging efficiency at low temperature.
  • The cycle life of high rate discharge and low DOD is long.

Characteristic of High Performance Factory Activated

High Performance Valve Regulated Factory Activated Lead Acid Battery is suitable for motorcycle starting and all kinds of electrical equipment requiring batteries to provide large current instantaneously in a variety of ambient temperatures, especially in the extremely low temperature.

OUTDO HC12A-MF Motorcycle Lead-Acid Battery — 12V 10Ah, maintenance-free, factory sealed

Factory Activated Safe Use Precautions

I. Warning


  1. The electrolyte inside the battery is corrosive and may damage metal, cotton products, and stone. Handle the battery properly.
  2. Do NOT place the battery on its side or upside down to prevent acid leakage.
  3. Hydrogen gas may be generated during battery operation and charging. If exposed to fire or sparks, it may cause an explosion. Please observe the following precautions:
    • Use and maintain the battery in a well-ventilated area.
    • Keep sparks and open flames away during battery maintenance.
    • If the battery is charged outside the vehicle, do not install it immediately after charging. Let it rest for at least 10 minutes to allow hydrogen gas to dissipate.
    • After riding, do not remove the battery immediately. Let it rest for at least 10 minutes.
    • During charging, the ambient temperature should not exceed 45°C. If it does, cool the battery with water or reduce the charging current and voltage.
  4. Do NOT place metal tools or conductive materials near the terminals to avoid short-circuiting.
  5. Do NOT strike the terminals with a hammer during battery installation.
  6. Handle the battery carefully during transportation to avoid impact or damage.

II. Factory Activated Installation and Maintenance


  1. Connect the positive terminal first. Do NOT reverse the polarity, otherwise the motorcycle's electrical equipment may be damaged.
  2. Activation Notice:
    • Some batteries may not be activated immediately due to differences in vehicle performance. Start the engine several times or gently apply the throttle to help activate the battery more easily.
    • Manual activation is recommended to ensure the exact activation date is recorded.
  3. During acid filling, wear acid-resistant clothing, rubber boots, safety goggles, and rubber gloves. If acid splashes onto skin or clothing, rinse immediately with a large amount of water. Seek medical attention if necessary.
  4. Do NOT over-discharge the battery. Recharge the battery promptly after it has been discharged.
  5. Disconnect the negative terminal if the motorcycle will not be used for a long period.
  6. Do NOT check whether the battery has power by short-circuiting the terminals.
  7. Regularly check the terminal connections and ensure the terminals are clean to maintain good contact.
  8. Store the battery in a dry, well-ventilated place at 5-25°C, away from direct sunlight. Keep the battery at least 2 meters away from heat sources. Check and maintain the battery regularly.
ModelSeriesVoltage (V)Capacity (Ah)Hour Rate (HR)Dimensions±2 (mm)PolarityWeight±3% (KG)TerminalRegular Charge Current (A)Meter CCA (25±5°C)CCA (-18°C)Datasheet
HC12A-MFFactory Activated121010150*86*104+ -3.65Z41370190PDF
HCX7L-MFFactory Activated127.510113*70*130- +2.65Z30.75190120PDF
HCX8L-MFFactory Activated12910113*70*130- +2.87Z30.9260140PDF
HCX12-MFFactory Activated121210150*86*130+ -4.15C121.2320190PDF
HCX14-MFFactory Activated121410150*86*145+ -4.78C121.4310210PDF
HCX14L-MFFactory Activated121410150*86*145- +4.78C121.4310210PDF
HCX16-MFFactory Activated121610150*86*161+ -5.45C121.6350240PDF
HCX16L-MFFactory Activated121610150*86*161- +5.45C121.6350240PDF
HCX24L-MFFactory Activated122410205*91*161- +7.42C132.4400350PDF
HCX30HL-MFFactory Activated123210166*127*175- +9.52C133.2480400PDF
HCX30L-MFFactory Activated123010166*127*175- +9.1C133440350PDF
HCZ5D-MFFactory Activated12510113*70*85- +1.64Z30.516065PDF
HCZ5S-MFFactory Activated12510113*70*85- +1.69Z30.519080PDF
HCZ7D-MFFactory Activated12610113*70*105- +2.16Z30.6190100PDF
HCZ7S-MFFactory Activated12610113*70*105- +2.2Z30.6220110PDF
HCZ10S-MFFactory Activated12910150*86*93+ -3.14Z40.9320170PDF
HCZ12S-MFFactory Activated1211.210150*86*110+ -3.63C121.12320190PDF
HCZ14S-MFFactory Activated121210150*86*110+ -3.9Z41.2380210PDF
HCZ20-MFFactory Activated122010177*88*155+ -6.2C132450270PDF
HCZ20H-MFFactory Activated122010177*88*155+ -6.46C132490310PDF
HCZ20HL-MFFactory Activated122010177*88*155- +6.46C132490310PDF
HCZ20L-MFFactory Activated122010177*88*155- +6.2C132450270PDF