A white Outdo OT200-12 gel battery, designed for energy storage. The battery has a white handle on the side and a label indicating it's a 12V 200Ah battery. The label also provides charging instructions and warnings.

Energy Storage Battery

Power Supply Battery

Advanced gel energy storage battery with low-Calcium/high-Tin alloy grid for corrosion resistance. Excellent cycle life, charging acceptance, and stable performance from high-purity materials.

OUTDO

Characteristic of Energy Storage Battery

1. Adopting low-Calcium & high-Tin alloy grid, high anti-corrosive performance, low battery gas evolution.

2. With special lead paste formula, our batteries have good endurance cycle capability and charging acceptance and good recovery performance after deep cycle use.

3. The fumed silica that is adopted as the key raw material of gel electrolyte is produced in Germany.

4. Batteries have long service life, good deep discharging cycle capability.

5. Gel batteries have better heat dissipation than AGM sealed batteries, reduced the possibility of thermal runaway.

6. The self-discharge of gel batteries is less than 1%/month.

7. The electrolyte inside battery equally distributed has no layering phenomenon and the electrolyte is not readily to dry up.

8. Battery producing adopts high purity raw material, advanced manufacturing equipment to ensure battery performance stability and consistency.

9. Battery electrolyte contains silica sol, so no dissociative acid or layering phenomenon inside, ensure the good low temperature performance and service life of batteries.

10. Battery design life of standby use at 25℃ is over 10 years.

A white Outdo OT200-12 gel battery, designed for energy storage. The battery has a white handle on the side and a label indicating it's a 12V 200Ah battery. The label also provides charging instructions and warnings.

APPLICATION

  • Solar Power Off-Grid System
  • Wind Power System
  • Traffic Light
  • Solar Power Energy Storage for Domestic Use
  • Navigation Light
  • Unattended Highway
  • Railway Communication Power Supply
  • Solar Power Street Lighting

Energy Storage Battery Safe Use Precautions

I. Battery Use

  1. Batteries are delivered fully charged. However, their capacity may gradually decrease during storage before installation. If the storage period is extended, the battery should be recharged. For storage periods of less than 6 months, recharge using a constant voltage with limited current at 2.27V per cell, with a maximum current below 0.25C, for 48–72 hours.
  2. Batteries can be used in both standby and cyclic applications. Charging should be performed using a constant voltage with limited current, with a maximum current of 0.1C₁₀ to 0.25C₁₀.
    • Standby use (25°C):
      • 2V cells: 2.25V/cell
      • 6V / 12V batteries: 2.27V/cell
    • Cycle use (25°C):
      • 2V cells: 2.35V/cell
      • 6V / 12V batteries: 2.40V/cell
  3. Ambient temperature has a significant impact on charging performance, battery capacity, and service life. If the temperature falls outside the range of 20°C–30°C, the charging voltage should be adjusted accordingly:
    • Decrease the charging voltage at higher temperatures
    • Increase the charging voltage at lower temperatures
    Correction factor: 4mV/°C per cell
  4. The battery should be recharged after installation or after discharge using a constant voltage with limited current:
    • Charging voltage (25°C): 2.35V/cell
    • Maximum current: 0.1C₁₀ to 0.25C₁₀
    If the battery is fully discharged (100% depth), the typical charging time is 24–27 hours. The battery is considered fully charged when:
    • The charging current drops to a very low level and remains stable for approximately 3 hours, or
    • The charged capacity reaches about 115% of the discharged capacity
  5. Equalization Charging: If the float voltage of any battery in the pack drops below 2.2V per cell, the entire battery pack should undergo equalization charging.
    • Charging voltage (25°C): 2.35V/cell
    • Maximum current: 0.1C₁₀ to 0.15C₁₀
    • Duration: 8–12 hours

II. Requirements of Installation and Use

  1. Batteries are generally used in series connections. If parallel connection is required, it should not exceed two parallel branches.
  2. Batteries can operate within an ambient temperature range of -25°C to 45°C. The recommended operating temperature is 15°C to 30°C. Ensure the battery room is properly ventilated.
  3. Keep batteries away from heat sources and sparks, maintaining a safety distance of at least 1 meter. Avoid exposure to direct sunlight, radiation, organic solvent vapors, and corrosive gases. To improve shock resistance, the battery rack should be securely fixed with foundation bolts.
  4. Batteries are delivered fully charged. During transportation and installation, prevent short circuits. Pay special attention to avoiding contact between battery terminals and metal parts such as racks or enclosures.
  5. When installing battery cables, use insulated tools and wear insulating gloves. Remove any personal metal items such as watches, bracelets, or rings.
  6. Ensure all connections are securely tightened. The recommended torque is 5–7 N·m. Loose connections may cause overheating or even fire hazards.
  7. Do not mix batteries of different models or capacities. During installation, carefully check that the polarity is correct:
    • Connect the positive terminal of the battery to the positive terminal of the charger
    • Connect the negative terminal of the battery to the negative terminal of the charger
    Ensure that the polarity is not reversed.

III. Requirements of Battery Working Maintenance

  1. During battery operation, the operator should maintain complete records, including battery voltage, current, ambient temperature, operating time, and other relevant data.
  2. Regularly inspect the condition of all connecting terminals. Ensure they are securely fastened to prevent overheating or fire hazards caused by loose connections or contamination on the connectors.
  3. Check the total float charging voltage. Use a voltmeter to measure the voltage at the battery’s positive and negative terminals, ensuring it matches the indicated float charging voltage and complies with the standard values for the current temperature.
  4. During operation, if any abnormalities occur—such as unusual voltage, physical damage (e.g. cracks or deformation of the container or cover), electrolyte leakage, or abnormal temperature—the operator should identify and resolve the issue immediately.
  5. Keep the battery surface clean by using clean water only. Do not use organic solvents. Ensure the battery is operated in a dry, clean, and well-ventilated environment.

Notes for Energy Storage Battery Use

  1. Do not disassemble or modify the battery.
  2. Do not dispose of the battery in water or fire.
  3. Always wear insulating gloves when connecting battery packs.
  4. Do not install, use, or store batteries in areas accessible to children.
  5. Do not use batteries of different brands, capacities, voltages, or mixed old and new batteries in series connections.
  6. Batteries contain acid. If the battery is damaged and acid comes into contact with skin, clothing, or eyes, rinse immediately with plenty of water and seek medical attention if necessary.

Related Products

TypeModelVoltage (V)Capacity (Ah)Hour Rate (HR)Dimension±2 (mm)Weight±3% (KG)TerminalPolarityDatasheet
GEL Energy Storage TypeOT4-12(GEL)/CN1242090*70*100*1061.61F1CPDF
GEL Energy Storage TypeOT5-12(GEL)/CN1252090*70*100*1061.68F1CPDF
GEL Energy Storage TypeOT7-12(GEL)/CN12720151*65*94*1002.19F1FPDF
GEL Energy Storage TypeOT7-12(GEL)/CN12720151*65*94*1002.19F2FPDF
GEL Energy Storage TypeOT8-12(GEL)/CN12820151*65*94*1002.32F2FPDF
GEL Energy Storage TypeOT9-12(GEL)/CN12920151*65*94*1002.4F2FPDF
GEL Energy Storage TypeOT9-12(GEL)/CN-A12920151*65*94*1002.53F2FPDF
GEL Energy Storage TypeOT10-12(GEL)/CN121020151*98*95*1013.28F2FPDF
GEL Energy Storage TypeOT12-12(GEL)/CN121220151*98*95*1013.54F2FPDF
GEL Energy Storage TypeOT18-12(GEL)/CN121820181*77*167*1675.18L1D
GEL Energy Storage TypeOT20-12(GEL)/CN122020181*77*167*1676.08L1DPDF
GEL Energy Storage TypeOT24-12(GEL)/CN122420175*166*125*1257.5L2EPDF
GEL Energy Storage TypeOT24-12(GEL)/CN122420175*166*125*1257.5T0EPDF
GEL Energy Storage TypeOT38-12(GEL)/CN123810196*166*173*17312.6T1DPDF
GEL Energy Storage TypeOT55-12(GEL)/CN125510228*137*211*21616.8T1CPDF
GEL Energy Storage TypeOT65-12(GEL)/CN126510350*167*173*17320.6T3DPDF
GEL Energy Storage TypeOT75-12(GEL)/CN127510260*168*212*21922.7T1CPDF
GEL Energy Storage TypeOT85-12(GEL)/CN128510260*168*212*21925.2T1CPDF
GEL Energy Storage TypeOT90-12(GEL)/CN129010307*169*208*21327T1CPDF
GEL Energy Storage TypeOT100-12(GEL)/CN1210010333*173*216*22230.5T3CPDF
GEL Energy Storage TypeOT100-12(GEL)/CN-A1210010333*173*216*22231.2T3CPDF
GEL Energy Storage TypeOT120-12(GEL)/CN1212010406*172*208*23736.6T2CPDF
GEL Energy Storage TypeOT150-12(GEL)/CN1215010484*170*241*24142.5WC
GEL Energy Storage TypeOT200-12(GEL)/CN1220010522*239*217*22260.2T3EPDF
GEL Energy Storage TypeOT200-12(GEL)/CN1220010522*239*217*22260.2WE
GEL Energy Storage TypeOT200-12(GEL)/CN1220010522*239*217*24260.2B6EPDF
GEL Energy Storage TypeOT250-12(GEL)/CN1225010520*269*220*22572.3T2EPDF
Deep Cycle TypeOT100-2(GEL)/CD210010171*72*206*2145.85B6A
Deep Cycle TypeOT200-2(GEL)/CD220010173*111*328*36513.4T5A
Deep Cycle TypeOT300-2(GEL)/CD230010171*151*333*36519.2T5A
Deep Cycle TypeOT400-2(GEL)/CD240010211*175*328*36726.5T5H
Deep Cycle TypeOT500-2(GEL)/CD250010242*173*329*36731T5H
Deep Cycle TypeOT600-2(GEL)/CD260010301*175*331*36538.2T5H
Deep Cycle TypeOT800-2(GEL)/CD280010409*177*330*36553.2T5I
Deep Cycle TypeOT1000-2(GEL)/CD2100010475*175*328*36562T5I
Deep Cycle TypeOT1500-2(GEL)/CD2150010401*351*343*38298.5T5J
Deep Cycle TypeOT4-12(GEL)/CD1242090*70*100*1061.61F1CPDF
Deep Cycle TypeOT5-12(GEL)/CD1252090*70*100*1061.68F1CPDF
Deep Cycle TypeOT7-12(GEL)/CD12720151*65*94*1002.19F1FPDF
Deep Cycle TypeOT7-12(GEL)/CD12720151*65*94*1002.19F2FPDF
Deep Cycle TypeOT8-12(GEL)/CD12820151*65*94*1002.32F2FPDF
Deep Cycle TypeOT9-12(GEL)/CD12920151*65*94*1002.4F2FPDF
Deep Cycle TypeOT9-12(GEL)/CD-A12920151*65*94*1002.53F2FPDF
Deep Cycle TypeOT10-12(GEL)/CD121020151*98*95*1013.28F2FPDF
Deep Cycle TypeOT12-12(GEL)/CD121220151*98*95*1013.54F2FPDF
Deep Cycle TypeOT18-12(GEL)/CD121820181*77*167*1675.18L1D
Deep Cycle TypeOT18-12(GEL)/CD121820181*77*167*1675.18B10D
Deep Cycle TypeOT20-12(GEL)/CD122020181*77*167*1676.08B10D
Deep Cycle TypeOT20-12(GEL)/CD122020181*77*155*1556.08T7D
Deep Cycle TypeOT20-12(GEL)/CD122020181*77*167*1676.08L1DPDF
Deep Cycle TypeOT24-12(GEL)/CD122420175*166*125*1257.5T0EPDF
Deep Cycle TypeOT24-12(GEL)/CD122420175*166*125*1257.5L2EPDF
Deep Cycle TypeOT26-12(GEL)/CD122620175*166*125*1257.8L2EPDF
Deep Cycle TypeOT26-12(GEL)/CD122620175*166*125*1257.8T0EPDF
Deep Cycle TypeOT26-12(GEL)/CD-A122620175*166*125*1258.05L2EPDF
Deep Cycle TypeOT26-12(GEL)/CD-A122620175*166*125*1258.05T0EPDF
Deep Cycle TypeOT28-12(GEL)/CD122820175*166*125*1258.5L2EPDF
Deep Cycle TypeOT28-12(GEL)/CD122820175*166*125*1258.5T0EPDF
Deep Cycle TypeOT33-12(GEL)/CD123320194*132*170*1749.9T1CPDF
Deep Cycle TypeOT35-12(GEL)/CD123520194*132*170*17410.5T1CPDF
Deep Cycle TypeOT35-12(GEL)/CD123520195*130*153*18010.35B8CPDF
Deep Cycle TypeOT35-12(GEL)/CD123520195*130*153*16610.35T1CPDF
Deep Cycle TypeOT38-12(GEL)/CD124010196*166*173*17312.6T1DPDF
Deep Cycle TypeOT65-12(GEL)/CD126510350*167*173*17320.6T3DPDF
Deep Cycle TypeOT75-12(GEL)/CD127510260*168*212*21922.7T1CPDF
Deep Cycle TypeOT85-12(GEL)/CD)128510260*168*212*21925.2T1CPDF
Deep Cycle TypeOT90-12(GEL)/CD129010307*169*208*21327T1CPDF
Deep Cycle TypeOT100-12(GEL)/CD1210010333*173*216*22230.5T3CPDF
Deep Cycle TypeOT100-12(GEL)/CD-A1210010333*173*216*22231.2T3CPDF
Deep Cycle TypeOT120-12(GEL)/CD1212010406*172*208*23736.6T2CPDF
Deep Cycle TypeOT150-12(GEL)/CD1215010484*170*241*24142.5T3CPDF
Deep Cycle TypeOT150-12(GEL)/CD-A1215010484*170*241*24144T3CPDF
Deep Cycle TypeOT150-12(GEL)/CD1215010484*170*241*24142.5WC
Deep Cycle TypeOT200-12(GEL)/CD1220010522*239*217*22260.2T3EPDF
Deep Cycle TypeOT200-12(GEL)/CD1220010522*239*217*22260.2WE
Deep Cycle TypeOT200-12(GEL)/CD1220010522*239*217*24260.2B6EPDF
Deep Cycle TypeOT250-12(GEL)/CD1225010520*269*220*22572.3T2EPDF
GEL Deep Cycle TypeOT55-12(GEL)/FT/CD125520291*106*223*23115.7T6EPDF
GEL Deep Cycle TypeOT75-12(GEL)/FT/CD127510562*116*187*19525.4T2EPDF
GEL Deep Cycle TypeOT100-12(GEL)/FT/CD1210010410*110*287*29531.7T2EPDF
GEL Deep Cycle TypeOT105-12(GEL)/FT/CD1210510507*110*224*23231T3EPDF
GEL Deep Cycle TypeOT150-12(GEL)/FT/CD1215010565*110*288*29645.3T2EPDF
GEL Deep Cycle TypeOT180-12(GEL)/FT/CD1218010561*125*316*31654.2T2EPDF
GEL Deep Cycle TypeOT200-12(GEL)/FT/CD1220010561*125*316*31659.5T2EPDF
GEL Long Life TypeOT33-12(GEL)/CL123320195*130*158*18010.35B8CPDF
GEL Long Life TypeOT40-12(GEL)/CL124010196*166*173*17313.9T1DPDF
GEL Long Life TypeOT55-12(GEL)/CL125510228*138*205*22216.8B2CPDF
GEL Long Life TypeOT55-12(GEL)/CL125510228*137*211*21616.8T1CPDF
GEL Long Life TypeOT65-12(GEL)/CL126510350*167*173*17322.9T3DPDF
GEL Long Life TypeOT100-12(GEL)/CL1210010333*173*216*22232.5T3CPDF
GEL Long Life TypeOT120-12(GEL)/CL1212010406*172*208*23738T2CPDF
GEL Long Life TypeOT150-12(GEL)/CL1215010484*170*241*24147.2T3CPDF
GEL Long Life TypeOT150-12(GEL)/CL1215010484*170*241*24147.2WC
GEL Long Life TypeOT200-12(GEL)/CL1220010522*239*217*22263.3WE
GEL Long Life TypeOT200-12(GEL)/CL1220010522*239*217*22263.3T3EPDF