Lithium-ion Energy Storage Battery
Power Supply Battery
Key Features of Our LiFePO4 Storage Battery
- Adoption of LiFePO4 cell— features Environmental-friendliness, Long service life, deep discharge, light weight, high security
- Fast charge and big current discharge—50A to charge, 120A to continuously discharge, 180A to peak discharge
- The high-waterproof design—above IP66, meets the use at harsh environment
- Easy to use and maintain— can be installed in any direction, maintenance free
OUTDO
Energy Storage Lithium Battery Features
LiFePO4 Storage Battery Safe Use Precautions
I. Safety Precautions
- Do not disassemble, repair, or modify the system. It contains sulfuric acid and lead, which can be harmful to people and the environment..
- Do not short-circuit the positive and negative terminals of the system or battery pack, as this may cause electric shock, fire, or equipment failure.
- Ensure that all terminal bolts are securely tightened. Loose connections may lead to overheating and increase the risk of fire.
- Keep the system away from oil, water, and other chemicals, as exposure may result in electric shock, fire, or malfunction.
- Always disconnect the main power supply before installation or wiring to avoid the risk of electric shock.
- Do not connect the system to a power source exceeding the rated voltage, as this may cause fire or damage to the system.
- Do not use the system directly as an AC power source. If AC output is required, use appropriate equipment such as a UPS.
- Keep the system away from flames, heat sources, and high-temperature environments to prevent the risk of explosion.
- During charging, small amounts of gas may be generated. Ensure proper ventilation and use the system in a well-ventilated area.
II. LiFePO4 Storage Battery Precautions for Use
- Do not store or use the system under the following conditions, as this may cause malfunction, acid leakage, or electrical hazards:
- Outdoor environments exposed to rain or direct sunlightใ
- Areas with heavy fog or freezing conditions.
- Locations with corrosive gases
- Highly humid or dusty environments
- Areas subject to strong vibrations or mechanical shock
- LCD Screen Maintenance
- Do not place heavy objects on or apply pressure to the control panel
- Keep the screen and interfaces clean and dry at all times
- Regularly check the system display for proper operation
- Pay attention to any buzzer alarms
- Respond promptly to any system alarms
Related Products
| Battery | Model | Voltage (V) | Capacity (Ah) | Standard Power (Wh) | Terminal | Polarity | Charge Current (A) | Fast Charge Current (A) | Max Current (A) | Dimensions±2 (mm) | Weight±3% (KG) | Lead-acid Battery Model | P/N | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 12V Type | CNLFP4-6 | 6.4 | 4 | 25.6 | F1 | + - | 0.8 | 2 | 2 | 71*48*100*T107 | 0.37 | OT3-12(GEL) | 302150036-00022 | |
| 12V Type | CNLFP4-12 | 12.8 | 4 | 51.2 | F2 | + - | 0.8 | 2 | 4 | 91*72*100*T105 | 0.53 | OT4-12(GEL) | 302150036-00023 | |
| 12V Type | CNLFP5-12 | 12.8 | 5 | 64 | F2 | + - | 1 | 2.5 | 4 | 91*72*100*T105 | 0.63 | OT5-12(GEL) | 302150036-00024 | |
| 12V Type | CNLFP6-12 | 12.8 | 6 | 76.8 | F2 | + - | 1.2 | 3 | 5 | 151*64*95*T100 | 0.8 | OT7-12(GEL) | 302150036-00017 | |
| 12V Type | CNLFP8-12 | 12.8 | 8 | 102.4 | F2 | + - | 1.6 | 4 | 5 | 151*64*95*T100 | 0.86 | OT7.5-12(GEL) | 302150036-00025 | |
| 12V Type | CNLFP10-12 | 12.8 | 10 | 128 | F2 | + - | 2 | 5 | 10 | 151*64*95*T100 | 1.11 | OT10-12(GEL) | 302150036-00026 | |
| 12V Type | CNLFP12-12 | 12.8 | 12 | 153.6 | F2 | + - | 2.4 | 6 | 10 | 151*100*102*T105 | 1.58 | OT12-12(GEL) | 302150036-00027 | |
| 12V Type | CNLFP20-12 | 12.8 | 20 | 256 | LC1 | + - | 4 | 10 | 20 | 184*79*172 | 2.93 | OT20-12(GEL) | 302150036-00005 | |
| 12V Type | CNLFP24-12 | 12.8 | 24 | 307.2 | LC2 | + - | 4.8 | 12 | 20 | 166*175*126 | 3.08 | OT24-12(GEL) | 302150036-00028 | |
| 12V Type | CNLFP30-12 | 12.8 | 30 | 384 | LC3 | + - | 6 | 15 | 30 | 197*166*173 | 4.4 | OT38-12(GEL) | 302150036-00072 | |
| 12V Type | CNLFP38-12 | 12.8 | 38 | 486.4 | LC3 | + - | 7.6 | 19 | 38 | 197*166*173 | 5.08 | OT38-12(GEL) | 302150036-00029 | |
| 12V Type | CNLFP55-12 | 12.8 | 55 | 704 | LC5 | + - | 11 | 27.5 | 55 | 228*138*215 | 7.3 | OT55-12(GEL) | 302150036-00030 | |
| 12V Type | CNLFP60-12 | 12.8 | 60 | 768 | LC4 | + - | 12 | 30 | 60 | 358*166*173 | 7.5 | OT60-12(GEL) | 302150036-00031 | |
| 12V Type | CNLFP65-12 | 12.8 | 65 | 832 | LC4 | + - | 13 | 32.5 | 60 | 358*166*173 | 7.8 | OT65-12(GEL) | 302150036-00032 | |
| 12V Type | CNLFP75-12 | 12.8 | 75 | 960 | LC5 | + - | 15 | 37.5 | 60 | 260*170*215 | 9.3 | OT75-12(GEL) | 302150036-00033 | |
| 12V Type | CNLFP80-12 | 12.8 | 80 | 1024 | LC4 | + - | 16 | 40 | 60 | 331*173*220 | 9.9 | OT80-12(GEL) | 302150036-00034 | |
| 12V Type | CNLFP100-12 | 12.8 | 100 | 1280 | LC4 | + - | 20 | 50 | 60 | 331*173*220 | 11.7 | OT100-12(GEL) | 302150036-00035 | |
| 12V Type | CNLFP120-12 | 12.8 | 120 | 1536 | LC4 | + - | 24 | 60 | 60 | 331*173*220 | 13.7 | OT120-12(GEL) | 302150036-00036 | |
| 12V Type | CNLFP150-12 | 12.8 | 150 | 1920 | LC4 | + - | 30 | 60 | 60 | 484*170*241 | 17.9 | OT150-12(GEL) | 302150036-00037 | |
| 12V Type | CNLFP200-12 | 12.8 | 200 | 2560 | LC4 | + - | 40 | 60 | 60 | 484*170*241 | 22.25 | OT200-12(GEL) | 302150036-00038 | |
| 24V Type | CNLFP50-24 | 25.6 | 50 | 1280 | LC4 | + - | 10 | 25 | 40 | 331*173*220 | 10.8 | / | 302150036-00039 | |
| 24V Type | CNLFP100-24 | 25.6 | 100 | 2560 | LC5 | + - | 20 | 50 | 60 | 522*240*222 | 23.1 | / | 302150036-00040 | |
| 24V Type | CNLFP120-24 | 25.6 | 120 | 3072 | LC5 | + - | 24 | 60 | 60 | 522*240*222 | 27.96 | / | 302150036-00041 | |
| 12V Type | CNLFP50-12(F) | 12.8 | 50 | 640 | LC5 | + - | 10 | 25 | 50 | 228*138*215 | 5.8 | OT50-12(GEL) | 302150036-00042 | |
| 12V Type | CNLFP60-12(F) | 12.8 | 60 | 768 | LC4 | + - | 12 | 30 | 60 | 260*170*215 | 6.8 | OT60-12(GEL) | 302150036-00043 | |
| 12V Type | CNLFP75-12(F) | 12.8 | 75 | 960 | LC4 | + - | 15 | 37.5 | 75 | 331*173*220 | 8.5 | OT75-12(GEL) | 302150036-00044 | |
| 12V Type | CNLFP100-12(F) | 12.8 | 100 | 1280 | LC4 | + - | 20 | 50 | 100 | 331*173*220 | 11.2 | OT100-12(GEL) | 302150036-00045 | |
| 12V Type | CNLFP150-12(F)+ | 12.8 | 150 | 1920 | LC4 | + - | 30 | 75 | 100 | 484*170*241 | 14.3 | OT150-12(GEL) | 302150036-00046 | |
| 12V Type | CNLFP200-12(F) | 12.8 | 200 | 2560 | LC4 | + - | 40 | 100 | 100 | 522*240*222 | 19.3 | OT200-12(GEL) | 302150036-00047 | |
| 48V Type | CNLFP50-48(F) | 48 | 50 | 2400 | TC1002 | + - | 10 | 50 | 50 | 484*430*134 | 25 | / | 302150036-00074 | |
| 48V Type | CNLFP80-48(F) | 48 | 80 | 3840 | TC1002 | + - | 16 | 80 | 80 | 484*500*178 | 40 | / | 302150036-00075 | |
| 48V Type | CNLFP100-48(F) | 48 | 100 | 4800 | TC1503 | + - | 20 | 100 | 100 | 484*500*178 | 42 | / | 302150036-00076 | |
| 48V Type | CNLFP120-48(F) | 48 | 120 | 5760 | TC1503 | + - | 24 | 100 | 100 | 484*500*223 | 54 | / | 302150036-00077 | |
| 48V Type | CNLFP150-48(F) | 48 | 150 | 7200 | TC2003 | + - | 30 | 100 | 100 | 484*680*178 | 68 | / | 302150036-00078 | |
| 48V Type | CNLFP200-48(F) | 48 | 200 | 9600 | TC2003 | + - | 40 | 100 | 100 | 484*550*223 | 85 | / | 302150036-00079 |